Guangdong Nanbowan Metal Building Materials Co., Ltd.
Ceiling Cleaning for Commercial Metal Ceiling Systems
There are a number of factors to consider when specifying and maintaining commercial metal ceilings. These include the panel finish, backing material and means of access. By defining these from the outset, the site team can safely strip the accumulated grime and target the replacement of any individual panels as necessary.
Stripping Commercial Metal Ceilings
Loosely adhered dust should first be removed with a dust mop or lint free fabric. Depending on the coating and backing, the panel can then be lightly dampened with a suitable low-grade detergent and subsequently rinsed and dried in line with recommendations. In the case of perforated panels, due consideration must be given to the nature of the backing and the avoidance of liquids entering the apertures.

Ascertaining the Finish
The relevant coating specification or submittals will set out the finish to the metal panels. Once a building has been refurbished, this becomes important as adjoining rooms may have been replastered to a similar hue but using a differing substrate. Images of the panel edge and exposed face will be a useful starting point to ascertain the range of panels fitted, pending the identification of the correct finish.
Finishes - Polyester Powder Coat, PVDF, Anodised
Each of these is a form of surface coating. Alternatively, the aluminum may have been anodized to form a natural oxide coating. Each will have an associated recommendation for cleaning products and their strength. Do not assume that a detergent suitable for a particular powder coating will also be appropriate to PVDF or anodized surfaces, despite potentially being indistinguishable.
As noted above, certain cleaning agents may leave a visible deposit upon the panel or otherwise alter its characteristics. Any trial should be assessed once fully dry and viewed under normal working light levels, as some effects of application (e.g. variation in sheen) may only become apparent once the panel is dry.
Determine if the Problem is a Deposit or Defect
Once the recommended procedure has been carried out and allowed to air dry, if a grey discolouration persists, the matter should be logged and no further action taken. The defect could take many forms, including the examples listed above. Further mechanical action will not serve to diagnose the root cause, so ensure the panel identity is retained with the log to enable the manufacturer to advise on remedial works or part-supply.
Establish the Recommended Procedure for Maintaining the Ceiling
On completion, the building management should receive the list of panels supplied to the scheme and the recommended method for their upkeep. Details of the procedure to remove dust, whether detergent may be employed and if rinsing and drying is required, should also be communicated.
Use of a Lint Free Cloth and Low Grade Detergent
Using a fresh lint free fabric or dust mop, remove all free-standing dust and particulates from the panel face. Failure to do so risks dragging these across the face during subsequent steps. Should staining persist and in accordance with the coating recommendation, prepare a solution of mild neutral detergent and warm water. Using a soft sponge or lint free cloth (thoroughly wrung), apply to the face of the panel.
Note again that for panels incorporating an acoustic fleece, the recommended approach for the full panel package must be established prior to introducing the wet regime. It is not sufficient to consider just the exposed metal.
Rinse, Dry and Proceed Along the Route
Should the protocol require that the face is rinsed, follow up with a cloth soaked in clean water to pick up the detergent. Thoroughly dry the face with a soft lint free cloth, taking care around the perimeter of each panel. When working along a length of ceiling, proceed panel-by-panel along one section. If required, the baffles can be cleaned from top to bottom to avoid tracking onto previously treated panels. Avoid directing any water into the void or adjacent services.
Assess the first 'dry' section as you progress, and identify any remaining problem areas. Log the location of any persistent issues and seek clarification as to the most appropriate course of action prior to advancing the level of intervention.
Considerations for Different Ceiling Configurations
The following table provides a brief overview of the various forms of metal ceiling and the implications for their maintenance and individual panel replacement.
Type of Ceiling | Cleaning | Part supply |
Clip-in | Refer to the recommendations for the coating. Adopt the recommended technique to liberate the panels from the hidden fixing. | May require special tools to facilitate release. Care must be taken to source the appropriate edge and fixing. |
Lay-in | Will typically sit within a visible grid and the exposed face can generally be cleaned (subject to the above). | Panel(s) can usually be removed for cleaning where practical. Will need to match the grid aperture, edge and fixing. |
Baffle | Fixation to the hidden carrier or hanging rod(s) will dictate how the blades are cleaned and accessed. | Identify the relevant fixing mechanism, geometry and pitch of the baffle. |
Perforated (with acoustic infill) | Can be clip-in or lay-in. Adequate dry technique (e.g. dusting, soft brush vacuum) will be required to maintain the exposed face. Avoid saturating the infill. | Same as above plus the perforation and backing. |
Acoustic Fleece
The term 'perforated' relates to the panel face only. As described above, the panel may be fixed clip-in or lay-in. Additionally, a range of infills can be accommodated behind the panel. It is therefore important to specify the aperture configuration and infill, and record this for reference in future.
Vacuuming
If permitted per the panel data, vacuuming with a soft brush head is advised. Ensure the vacuum tip does not come into direct contact with the panel face. Where a moisture sensitive infill is fitted, avoid using the wet regime as a standard practice. Only employ the damp procedure if explicitly sanctioned by the panel manufacturer for the full panel construction. Avoid over-saturating the infill.
Dampness Behind the Panel
Even where the exposed face appears completely dry, the infill could be wet. Examine any affected infill prior to re-installing the panel. If other works are being undertaken close by, e.g. cutting into the ceiling, take precautions to prevent contamination of the existing fitment. Ensure the correct infill is sourced for any new parts ordered.
If the facility team requires access to the plant room above the ceiling, the technique adopted by the installer to remove the panels will be relevant. Ensure that liberated panels are placed on a clean surface, not directly on their face. Record the location of each panel if they are not mutually interchangeable. Never permit operatives to climb onto the face of the ceiling to gain access to plant.
Expected Frequency of Cleaning
Obviously, a standard RC ceiling will require a different regime. With a metal ceiling, the key factor is how rapidly the face of the panel(s) becomes encrusted. As part of the initial inspections, compare the rate of accumulation in different locations (e.g. circulation route vs. under commercial cooker hoods). Based on this, the client's site team can formulate a baseline program for the remainder of the asset.
Dry Areas, High Footfall, Commercial Extraction and Swimming Pools
Depending on the occupancy, a typical office may simply require occasional dusting. In a retail environment, check the illumination and extraction points for signs of build-up. Under a commercial cooking hood, there is likely to be a sticky deposit which dusting alone will be unable to address. Similarly, at a swimming pool, it may be necessary to differentiate between surface contamination and persistent evaporation.
Impact of Darker Colors
Clearly, darker colored panels will reveal any dust more readily than e.g. the off-white route serving the plant area. The former may therefore warrant inspection at a higher frequency. However, there is no implication that a different range of cleaning chemicals should be used or that the life of the product will be shortened.
Suitability of Alternative Products
Any chemical formulated for cleaning e.g. mirrors, chrome and stainless steel should only be considered for use on the ceiling after checking its suitability for the relevant coating.
Do Not Use...
It is advisable to exclude any harsh scouring media (including scouring pads and wire brushes) from the building's cleaning inventory. Likewise, strong solvent-based, highly alkaline and oxidising products (paint stripper, acids, caustic soda, bleach, ammonia...) and high pressure water jets may not be appropriate. Always refer back to the data for the relevant finish and panel make-up.
Conduct Trials with Unfixed Panels
Ideally, an unfixed panel of identical specification to that in situ can be made available to carry out any proposed test. If the supplier is willing to sanction this, ensure the trial product, concentration and post-dry result are recorded. If an equivalent stockholder is unavailable, hold off and await further instruction. Do not use the ceiling in situ as a trial!

Further Information from Nanbowan
Nanbowan manufacture metal ceilings to suit the specific geometry of the customer's space. Whether installing a new fitment or seeking to replace an existing one, our team can assist with determining the optimum panel range and finish.
Finish Selection
Having determined the form of fix and desired panel edge, the customer can select the panel size, finish and (if applicable) aperture and infill. We can offer a variety of powder coats, PVDF, anodized and effect finishes. Any part-order will need to ensure a suitable interface with the existing ceiling as well as meeting the required aesthetic.
Ordering
When requesting a quote, please supply the ceiling layout or product code, panel size, gauge and volume, along with the desired finish. A picture of the face of the panel may be helpful to indicate the tone and apertures, while an image/drawing of the edge will assist in establishing the connection. Note that infill and method of fix will need to be provided.
To facilitate a color comparison, please provide a sample (or mutually agreed reference) and a proposed panel can be assessed next to the in-situ fitment. Please bear in mind that the age of the existing product, level of sheen and orientation of the finish may limit the ability to achieve a 100% match. Finally, please advise of the expected volume of parts and any lead time/approval requirements.
Summary
Providing an appropriately selected and accessible metal ceiling to meet the application is the prerequisite to effective housekeeping. The customer should specify the required range and ensure the site team is informed of the appropriate protocol for maintaining the fitment. Speak to our team to enquire about the range of products, finishes and part-supplies.
Frequently Asked Questions
Will Nanbowan be able to supply a like-for-like match to my current ceiling?
Yes, provided we can agree a reference point for the required tone. Please supply the relevant coating, degree of sheen, profile and orientation (if any), in addition to the desired color. A trial panel can then be viewed in-situ to confirm acceptability. Note that the age of the existing fitment may preclude a true color match.
What are the principal differences between the various ranges of metal ceiling?
As discussed above, clip-in and lay-in panels differ primarily in terms of their method of fixation. Baffles comprise a series of blades which are hung vertically from the ceiling. The customer should therefore be aware of these attributes when considering the most suitable solution.
Are acoustic metal ceiling panels available as individual units?
In many cases, subject to the means of fix. The new part(s) should correspond in all respects with the existing, i.e. size, edge, apertures, finish and infill. While there may be a near-identical product in terms of the bare metal, the alternative infill may give a significantly reduced acoustic performance. The full panel should be confirmed with the manufacturer and project team.
What frequency of housekeeping will be required?
This will be a function of the data supplied by the manufacturer and the degree of soiling observed in each location. Should one area require attention considerably prior to the next scheduled opportunity, a targeted assessment should be made at that point to determine if the overall frequency needs to be increased.
Can I leave my existing ceiling in place?
Dependent on the surface being addressed and the level of access available. In some circumstances, the team may be able to undertake the works with the panels left in-situ. If the problem arises above the ceiling (e.g. soiling to the underside of the panels or saturated infill), an alternative means of access will be required.