Guangdong Nanbowan Metal Building Materials Co., Ltd.
Facade Maintenance and Replacement Planning for Commercial Aluminum Cladding
It is important to undertake a detailed inspection when considering the future maintenance or replacement of commercial aluminum facades. From this, you will be able to determine if there is a need to clean, repair or replace the cladding, and as necessary specify new panels.
As above, initial inspection of the facade should focus on the condition of the panels, joints, outlets and fixings. Only once this has been established can the scope of works be confirmed, and new aluminum panels (if applicable) be ordered.
Considerations When Considering New Aluminum Curtain Wall/Cladding
Firstly, consider whether the failure relates to the exposed aluminum face or to other associated elements such as jointing, fixings and weep holes. The building's maintenance logs will typically highlight the specific defect and associated element(s) to be addressed. It is therefore unlikely that simply replacing a single panel will address a failed joint or other cause.
Joint Separations
If there is separation of the seal at an edge, cracking of the sealant or loss of seal within a gasket, these are all indications of potential joint issues. Similarly, although the presence of a discolouration beneath a joint will help pinpoint a defect, its location in isolation will not be conclusive.
Review the relevant joint detail and establish the intended configuration of joints and apertures. If a previous remedial works exercise has taken place, it may be possible to source a suitably matched jointing product locally. It is advisable to agree the extent of remedial works required prior to placing an order for new panels.
Weep Holes and Fixings
Blocked or contaminated weep holes may impede drainage from the facade, again with no direct impact to the panel. Any apparent movement, corroded or compromised fixings should be further investigated, and any necessary remedial action incorporated into the design for the replacement panel(s).
Requirements for a Replacement Panel Order
In order to source a replacement panel that can interface correctly with the existing facade, the following information should be provided to the manufacturer: co-ordinated panel dimensions and elevations, images and finishes. Note that an image of the panel face will generally not be sufficiently informative for production purposes.
Further Panel Information
In addition, you should be able to identify the panel number, elevation and position within the bay, panel face size, thickness and alloy (where applicable), and any folded edges, mitred corners, reinforcement, fixings and punched or cut features. Ideally the manufacturer will receive an approved panel drawing and/or an intact panel from site. All significant dimensions should be double-checked by your design team.
It is also important to clarify if the quote is limited to panel supply, or whether any additional associated fixings and trims will be supplied. You should liaise with the site team regarding the method of removing any overlying panels. This will aid clarity as to what is supplied and what works are expected to take place on-site.
Finishes and Quantities
You should provide the relevant finish and tints, and ideally an original reference panel, along with suitable imagery of the completed wetted facade. Once the panels have been exposed, it is common for the tint to vary significantly compared to the original. Accordingly, a new reference panel should be compared to the adjacent existing panels.
Quantities should be provided per panel family and dimension, allowing for any agreed buffer. Please advise the point of delivery and target site availability. The manufacturer should then be asked to comment on the viability of the order, sample turn-around period and manufacturing timescales. As noted, no fixed minimums or guaranteed delivery periods apply to a panel replacement order.
Evaluating the Panel and Finish
Where possible, inspect the facade under dry conditions and consistent daylight. Wet panels can exhibit a deeper color or mask areas of poor finish. In the absence of certainty, the applicable coatings schedule for the project will form the basis of the evaluation. An overview of the key differences between PVDF and powder coated aluminum can also be helpful.

Common Defects
These may include chalking, which will result in some level of free-standing debris on the panel, or fading, i.e. permanent color loss following due and approved washing. Other forms of damage may manifest as scratches (following a sharp line) or larger blistered and flaking areas. It is prudent to compare the affected dry and washed area against an available reference panel and/or protected area of facade. Document the scale of the impacted area to enable the finisher to propose a remedial course of action and the purchaser to make a considered assessment.
Depending on the nature of the defect, a complementary top-up of the finish may be appropriate (subject to the finisher's guidance). However, even here, the remedial work will likely be discernible when viewed against the remainder of the facade. Where the defect extends beyond the coating e.g. due to a distorted section adjacent to a fixing, the connection should be reviewed and a decision made to retain, remediate or replace the panel.
Having determined the extent of the defect(s), and referencing the details of the original panel(s), the replacement item(s) can be specified. Only then can quotes be obtained from manufacturers.
Selecting a Manufacturer for Panel Replacements
There are a number of factors to bear in mind when assessing potential suppliers. Clearly, if their quote does not include all relevant fabrication and finishing requirements and ancillaries, the comparative unit price is less meaningful.
Ensure they can manufacture the required items to the existing project's requirements. Request confirmation from the architect and site team that the alternative panel will interface satisfactorily with the existing support. Of course, simply comparing the dimensions of the panel face will not be adequate.
Agree Sample(s) and Terms of Supply
Obtain a finish sample, and potentially a further "proforma" panel, for approval prior to the main order. Specify the order size and enquire about any applicable minimum order levels, packaging and transit arrangements. Ensure that the final panel drawing and finish sample are recorded against the order.
Maintenance Log
For every set of images taken of the facade, note the date, position (i.e. elevation and bay) and subsequent action required. This will be valuable to the site and purchasing team when sourcing the replacement order, and ensure it is linked to the appropriate panel, finish and sample.
Recording Actions
The maintenance team should maintain a simple database to record the defects identified, remedial course of action taken and person signing off each activity. On completion of the replacement order, record the manufacturer, PO reference, panel drawing and finish sample. In doing so, a comprehensive data-set can be built up for the benefit of any future purchasers.
Spare Panels
Should spare panels be supplied as part of the initial tender, ensure any storage and handling guidelines and associated finish information is retained. Maintaining a basic database of the range, dimensions and number of spare panels on site can prove beneficial in the event of a subsequent incident. The extent to which a greater level of stock should be held will depend upon the client's strategy. No minimum stockholding or lead-time can be prescribed.
Alternatively, if the product has since been discontinued, commence the process using the relevant panel drawing and remaining reference panel. As noted above, the existing sample may have darkened or degraded and will require comparison to a newly agreed sample.

Other Forms of Aluminum Cladding
Nanbowan manufacture solid panels with a range of available coating options including PVDF, powder, timber and stone effect. The product is highly configurable to meet the dimensions, geometries and coatings detailed on the client's drawings, providing the platform for a productive dialogue with site and design team.
Selecting a Suitable Cladding and Coating
Based on the anticipated exposure and desired aesthetic outcome, select the appropriate panel and finish combination. It is good practice to consider the two in tandem. Some levels of soiling can be removed by rinsing the facade with fresh water. Further instructions should be followed as advised by the coating house, and care should be taken not to generalize the suitability of all types of contamination and patterned finishes.
Project Drawings and Finish Sample
Our technical team can review the project's documentation and produce a range of samples for your approval. When enquiring about a specific panel to replace, please quote the original geometry, sizes and method of fixation. We can then discuss how to achieve the closest possible color match to the relevant sample. The sampling process will allow your team to verify the proposed geometry and finish.
Of course, further hidden geometries and fixation points may be evident from the project's original documentation. These, combined with the selected finish, will enable us to confirm the details of the replacement and the associated contents of the order. Spare panel(s) can similarly be requested and labeled accordingly.
Please forward the applicable panel schedule, panel drawings and dimensions (or in-house measurement) and finish for us to provide a proforma. In the case of a low volume replacement order, this stage will be an appropriate opportunity to establish production capability and commercial terms.

Summary
By following the steps outlined above, you will be in a position to determine which elements of your aluminum facade can continue to be used and which will require replacement. Provided you have robust documentation and a validated finish and order content, we will be happy to assist. Get in touch to find out more about our aluminum products, discuss a sample or request a quote.
Frequently Asked Questions
Will my stained panel require replacement?
Not always. As described above, the source of the contamination should be identified and appropriately dealt with. If the panel is otherwise fit for purpose, there is no justification to replace it with a new face.
How can I ensure my replacement panel matches the existing?
We can reference the relevant finish, tint and sample, although the degree to which this can be achieved will be impacted by the passage of time. Once a sample has been agreed, please view it in natural light on-site for final confirmation.
Is it possible to replace individual panels?
In some instances, yes. The sequence of removal of surrounding and superimposed elements will need to be confirmed, and will be set out on the relevant installation drawing.